TRACER 1206/1210/1215 ——Maximum Power Point Tracking Controller Installation and Operation Manual Thanks very much for selecting our pr
7 Connect load positive (+) and negative (-) to the TRACER load output as shown in figure 3-2. An in-line fuse holder should be wired in series in
8 Step 3:Solar Wiring WARNING: Risk of electric shock! Exercise caution when handling solar wiring. The solar module(s) high voltage output can cau
9 Figure3-5 System Wiring Review Step 6: Install Fuses Install a more than15 Amp DC-rated fuse in each fuse holder in the following order: 1. Loa
10 4 Operation 4.1 MPPT Technology The TRACER utilizes Maximum Power Point Tracking technology to extract maximum power from the solar modu
11 Figure 4-1 shows a typical current VS. voltage output curve for a nominal 12V off-grid module. Current VS. Voltage in 12V system
12 Figure 4-2 shows the sequence of the stages. Figure 4-2 TRACER MPPT charging algorithm ·Bulk Charge In this stage, the battery voltage has not
13 ·Equalize WARNING: Risk of explosion! Equalizing flooded battery can produce explosive gases, so well ventilation of b
14 ·Charging State Indicator The green LED indicator will light whenever sunlight is available for battery charging, the green charging LED will sta
15 4.4 Setting Operation . Load Control Settings 1. Dusk to Dawn (Light ON+Light OFF) When solar module voltage goes below the point of N
16 Press the Setting Switch, and the led will switch between load 1 timer, load 2 timer and battery type. Press the Setting Switch for 5 seconds w
TRACER Dimensions Specification Summary System Voltage 12V DC / 24V DC*1 Rated Battery
17 If either of the two loads is TEST MODE. The two loads will be TEST MODE simultaneously.
18 ·Load Short Circuit Fully protected against load wiring short-circuit. After two automatic load reconnect attempts (10 seconds between each attem
19 5.2 Troubleshooting Troubleshooting according to the following instructions: Faults Possible reasons Troubleshooting Charging LED indicator is
20 Note:If no charging LED indication when the connection is normal Measure the PV input voltage at the PV terminals, input voltage must be greate
21 6 Warranty The TRACER-MPPT charge controller is warranted to be free from defects for a period of TWO (2) years from the date of shipme
22 7 Technical Specifications • Electrical Description Parameter Nominal system voltage 12VDC or 24VDC Rated battery current 10A Battery voltage ran
23 • Threshold Voltage Description Parameter NTTV (Night Time Threshold Voltage) 5V; x2/24V DTTV (Day Time Threshold Voltage) 6V; x2/24V Table7-3 T
Contents 1 Important Safety Information ... 1 2 General Information ...
1 1 Important Safety Information Save These Instructions This manual contains important safety, installation and operating instructions for TRACER.
2 2 General Information 2.1 Overview Thank you for selecting the TRACER controller which represents advanced technology of our company. The
3 The features of TRACER controller are shown in Figure 2-1 Figure 2-1 TRACER features. 1 – Charging status LED An LED indicator th
4 2.2 Optional Accessories Remote Meter(Model:MT-2) The digital Remote Meter displays system operating information, error indications, and self-diag
5 Step 1: Choose Mounting Location Locate the TRACER on a vertical surface protected from direct sun, high temperature, and water. Step 2: Check for
6 NOTE: The TRACER is a negative ground controller. Any combination of negative connections can be earth grounded as required. Grounding is reco